PVSyst calculations and simulations are run for complete and accurate output estimates. Opsun provides their clients optimized solutions that ensure a maximum return on investment for every system.
Structural and environmental assessments help clients determine the feasibility of a proposed project before investing too much time and money into it. Geo-localisation is used to model neighbouring buildings and evaluate shading issues.
Data from wind tunnel tests of Opsun’s mounting systems and engineering calculations, in addition to the building code, help structural engineers determine the correct required amount of ballasting/anchoring. The evaluation of wind zones as per the building code and load analyses that takes account of snow and wind loads streamline the rubber stamping process.