Key specifications
Material
Max Snow Loads
Max Wind Loads
Tilt Angle
PV Panel Orientation
Module
Ballasted
Anchored
Hydrid (ballasted & Anchored)
Dead Loads on roof (Ballasted)
Dead Loads on roof (Anchored)
PV Panel height from roof
Certifications
Interrow distance
Grounding
Roof Type Compatibility
Gains bifaciaux typiques observes
Wind deflector
HIGHEST PV MODULE DENSITY
Opsun SunRail™ East-West configuration allows fitting the highest PV module count on a roof, significantly increasing the W/sq foot ratio. Perfect fit for projects where local incentives are based on DC sizing and not on energy generation.
LOWEST BALLAST REQUIREMENT
With the PV modules orientated East and West acting as a wind deflector, coupled with Opsun’s extra strong rail-base racking system, this configuration allows for the lowest ballast requirement on the market. If you need a super light solar system, Opsun SunRail™ is the product you need.
SAVE ON INSTALLATION COST
Coming as 25 FT long rails with all components pre-assembled, Opsun SunRail™ racking system is the fastest to deploy on the roof. It allows saving 20% to 30% of the time you would need to install standard PV support systems. Less time on the roof, faster project delivery and commisionning make solar projects much more profitable.
Fewer ballasts and anchors per PV
Full Aluminum Design
Perfectly Safe for the roof
Fully Adjustable System On-Site
Better Panel Protection
Highest Standard for Engineering & Support
Our engineers use only the safest methods of calculation, to assure maximum solidity and durability of the structures. We have proprietary, recent wind tunnel tests with Western University, and we design using the latest Building Codes (ASCE-7-16, NBCC 2016, IBC 2018), as well as SEAOC PV2 notions of array size versus roof size to account for extraordinary vortices. Minimal deflection allowed on rails, and finite element analysis done with high-end 3D engineering software. Each zone ballast & anchors calculated individually. We find solutions to each unique challenge, and we react quickly if unforeseen events happen during construction (such as unmarked drains, roof equipments obstruction and last-minute changes).
ject-Specific Building Permit Plans & P.Eng stamp with each project
Custom, project-specific building permit plans, stamped by a local P. Eng., are provided for each job, describing step-by-step where each component goes, on the exact project site, with markups, details and explanations custom to each project's specific difficulties.
Documents & Specifications
OPSUNTM Total Engineering Support
Flexible Design
Opsun's racking is not a single product : it is instead a large library of rails, components and configurations that we can adapt to match any client's requirements.
Full engineering Support
Opsun experts takes care of all the mechanical aspects of your solar PV project and we deliver detailed, project-specific set of engineering plans to help accelerate installation time.
Technical Solutions
Opsun is your solution finder to a wide array of challenges, such as limited roof capacity, directly attached or hybrid (both ballasted & anchored) systems.
Installation Support
Opsun On-Site Support allows your installation team to benefit from the instructions and supervision of an expert from Opsun's team, with 15 years of experience.